RE: NSF certified water pitchers for copper reduction

5 aaa Contarninant Testing NSF info at this page indicates that filters certified for copper reduction can take 2 3 ppm or 3000 ppb level down to 1300 ppb. Not good enough for peapie with Wilsan Disease who need copper <100. None of the filters certified to remove copper that | can see are also certified to remove lead. Lisa is at a meeting in WI. She can confirm if she’s able to see her e-mail,

Re: NSF certified water pitchers for copper reduction

Linda and Lisa---Just following up. Do the filters that | send you in lat evenings email for Dr. C reduce copper to below 100 PPB, and if so, are they NSF certified to m=remove lead also? | promised Dr. C | would follow up with her about this---even though | am concerned about need to directly link with the providers. Eden

Re: STAT:Brita SAFF-100 faucet filter and other Brita faucet water filters

To
Unknown recipient
itis certified NSF/ANSI 53 Drinking Water Treatment Units - Health Effects xxxEND_PAGE:executiveofficeemails20_b1021_2680_2683_2 The Brita Products Company 1221 Broadway Oakland, CA $4612 United States 800-24-BRITA Facility : # 1 Brampton, Ontario, Canada Replacement Service Cycle Flow Rate Brand Name / Trade Name / Modet Element (gallons) (gpm) Faucet Mount Brita Faucet Filtration System SAFF-100 FR-200 400(4) 58

STAT:Brita SAFF-100 faucet filter and other

Brita faucet water filters STAT: need to be sure his model NSF certified Sent from my iPhone Begin forwarded message: Claim 2,4-D Reduction Asbestos Reduct Alachlor Reduct Atrazine Reduct Benzene Reduct Carbofuran Red Carbon Tetrachi Chlordane Reduc Chiorobenzene { Endrin Reductior Ethylbenzene Re Lead Reduction Lindane Reducti Methoxychior Re O-Dichlorobenze Simazine Reduct Styrene Reducti Tetrachtoroethy Toluene Reducti Toxaphene Red Trichloroethyter Trihalomethane: Turbidity Reduc: VOC Reduction xxxEND_PAGE:executiveofficeemails20_b1021_2680_2683_3

Re: STAT:Brita SAFF-100 faucet filter and other Brita faucet water filters

To
Unknown recipient
this certified NSF/ANSI 53 Drinking Water Treatment Units - Health Effects The Brita Products Company 1221 Broadway Oakland, CA 94612 United States 800-24-BRITA Facility : #1 Brampton, Ontario, Canada Replacement Service Cycle Flow Rate 2 xxxEND_PAGE:executiveofficeemails20_b1014_2669_2672_2 Brand Name / Trade Name / Model Element Faucet Mount Brita Faucet Filtration System SAFF-100 FR-200 {gallons} 100(1) {gprm) 58

Lead removal filters

Eden, To answer your questions: - Ifa filter is certified to Standard 53 it has different certifications for the contaminants that are removed. None of the faucet mount filters are certified to remove copper but | am attaching a performance data sheet for a Brita faucet filter (someone mentioned Brita filters) which is certified to remove lead. - Lead occurs in a dissolved and particulate form depending on the pH. The filters are tested at pH 6.5 and 8.4 and at differing alkalinity. - lam attaching a copy of the Brita faucet filter performance data sheet — | do not know if this is particular model that was given out. - This filter was tested to remove lead at levels of 150 ppb in water for 100 gallons reducing it to 10 ppb which is less that the EPA action level of 15 ppb . - It has an indicator light that turns for green to yellow to red indicating how much life the filter has remaining. The filter turns red at 100 gallons but it is tested to remove 120 gallons as a safety factor. Lisa Lisa Quiggle, Toxicologist MDHHS-Division of Environmental Health Capitol View Bldg, 4th Floor, Office 4-052 201 Townsend St. Lansing, MI 48913 (517) 373-4889 xxxEND_PAGE:dhhs02_b1298_4822_4822_1

RE: Director's Office Assignment -- Flint - need update asap

1 xxxEND_PAGE:deq21_b009_0009_0011_1 Linda Thanks for the additional information. As a follow-up to my earlier message, the National Science Foundation is apparently arranging funding to several investigators to evaluate the engineering aspects of the Flint water system to find a solution. Although Flint has initiated plans to construct a water line that will tap into Lake Huron as their water source, they may still have issues with their aging water distribution system. NIEHS wanted to know if ATSDR, MDHHS, or Flint Health Dept is planning to evaluate the public health implications of the problems in the water system. As you know, NCEH has both a Safe Water Program and a Lead Program that could possibly be involved, but only at the request of the state. If the elevated lead exposure is limited to just this one residence that has since been remediated, then federal involvement would not seem to be appropriate. Let me know if there is something more to evaluate. Mark