FW: Contract S-4002 100% and S-4003 90% Submittals - MDEQ comments

Matt, What is the status of the revised spec. or addendurn that spells out the weld testing methodology? (based on your June a5" message below) issuance of the Act 399 permit for Contract S-4002 is pending receipt of the revised spec or addendum. Michael Prysby, PE. District Engineer Office of Drinking Water and Municipal Assistance 517 290-8817

RE: Contract S-4002 100% and S-4003 90% Submttals - MDEQ comments

That sourds great. Yes | was informed of the testing methodology yesterday. | discussed this with American yesterday and | believe we are doing the magnetic particle testing. Once this is verified | will let you know and send the revised spec, These will either be in the addendum or on the original spec if we get it out prior te bidding. One way or another it will get placed in the spec. 1 xxxEND_PAGE:deq25_b124_1164_1166_1 As for the surge. Yes i spoke to the PM team yesterday and they are in the process of responding. | do not see any problerns with providing a quick response.

RE: Contract S-4002 100% and S-4003 90% Submttals - MDEQ comments

Matt, We do not have an objection with KWA wanting to use the more conservative leakage formula for the pipeline as opposed to the formula provided in AWWA C-604. We are also not opposed to the exclusion of the welded joints in the formula; however, since this results in a much lower leakage tolerance... all welded joints need to be properly tested. The specification should clearly state an acceptable testing methodology such as radiography, sonograms, or magnetic particle testing. Finally, it is our understanding that we will be receiving a response from Genesee County concerning our questions/comments from the updated surge analysis. Michael Prysby, PLE. District Engineer Office of Drinking Water and Municipal Assistance 517 290-8817 Sent: Tuesday, June 24, 2014 6:05 PM

RE: Contract S-4002 100% and S-4003 90% Submttals - MDEQ comments

i would like to revisit the conversation this morning regarding the pressure test. The new leakage method based on AWA GIM-11 the 66” nipe would allow 55 gal/mile leakage ina 2 hour pariod. The current specified method in section a2315 would allow roughly 0.2 gal/mile leakage ina 2 hour period depending on the pressure [150 to 350 psi) and the(} number of juints b ger mile to £2 per mile (welded isints do not count so only the valves count on the 66” fine, but if you count the hydrants, and air release valves, which are not normally courted, it could be 6-12 par mile depending on the section}, Note that you would have to have about 165 joints per mile {an average of 1 joint every 32 feet) @ 350 psi te equal the 55 gal per 2 hours allowed bry the new formula. For 150 psi, it would have to have the equivalent of 252 joints per mile to get the 55 gal leakage in 2 hours that is alowed by the new method. The current specification indleates to test ai the pressure equal to the pressure ciass listed on the drawings, where the new version would say test at no more than 125% of the working pressured. The working pressure is not defined anywhere so is that the pressure class of the roe, or the oressure within the pioe that is expected during operation? The 60” would be somewhat similar to the 66°, except the pressures would be lower on the 60" pipe. With that being sald will the MDEQ allow the current specifications to remain or do we need te still reference AWWA 604-41 for testing even though the allowable leakage is well above what we are allowing.

S-4004 MDEQ comments

Matt: Attached is the PDR you requested. I took the initiative to include drawings with the septic location and the size of the overflow cone that MDEQ requested in case they wish to expedite matters. These will also be included in the addendum. Due to the size of the files, please confirm receipt. Thanks Cliff Clifferd M. Genion BE. CGWE Principal Director of Groundwater of Environmental Modeling Cell: 419-509-7520 Phone 419-473-9611 FAX: 419-473-8924 Visit our Website: BAH INOS COM EVERY DAY 1460 children die from diseases directly related to unsanitary drinking water... Give water... give iffe, cc; Lynnette Meinz Thatp(es then 465 Date: 3/30/2014 9.44 AM

RE: S-4004 MDEO comments

Dard, | don't know Nyou received my response an the 25" but l want to make sure Vou are aware that | ari taking care of your concerns. On the 25’? laweote that we will Incormorate the drawing modifications into an addendum. Once the addendum is distributed we willce the MOEO. ‘This should address jrenis 2 and 3. Dadi ete PDF of the final POR and provide @ hand cony and tigital coy for your use.

S-4004 MDEQ comments

Matt, Based on our review, the following isaues remairy a) The Engineers response to our comment #3 indicated that the PDA had been corrected, However, we did nol receive an updated copy of the POR, and thus have no way te confi thet ib was corrected, 2) The Engineers response to aur coranient #6 indicates that the septic tank wes tn be relocated per aur request, The plans that we received show na change in the location of the septic tank, 3) The detail of the tunk overflow was added buck to Sheet P19, however It contains twa dimensions on the overflow weir cone that are listed ac "as req'd”, This iscue is the same as that for the sizing of the tank, MDEC canned issue a permit for “as reas”. Please note thet | will be oul of the office next week and will return on Agri 7). Thanks, Dard J Gotham PE. Michigan Demernaent of Environmental Quality Olice of banking Wailer & Municipal Assistance Saninaw-Bay Distict Ohics 404 Kelchuin Street, Suse b Bay City Bl 48708 BEO-4250.98 146 (Phone) BEU-BAT-821 8 (Fae ee Sent: Monday, March 24, 2014 6:28 AM

S-4004 Response to MDEQ comments.

Matt: Attached are the response to PM and MDEQ comments. 1 will try to provide a draft of the meeting minutes later today. Clitf Cifford 0. Gordon BE. COW Principal Director of Groundwater el Environmental Modeling Cell: 419-509-7520 Phone 419-473-9611 FAN: 419-473-8924 Visit our Website: www ineng.com EVERY DAY 7400 children sie from diseases directly rlated to unsanitary CAnking water. Give water give ifs. Soe

Re: FW: KWA - LHWI Septic system

Matt: You wanted to be kept informed. Please see below and attachment. Cliff CHffont M. Gordon BE. CGWP Principal Director of Groundwater & Environmental Modeling Cell: 419-509-7520 Phone 419-473-9611 xxxEND_PAGE:deq11_b416_1893_1896_1 FAX: 419-473-8924 Visit our Website: erenn jneng.com EVERY DAY 1460 children die from diseases directly related io unsanitary drinking water... Give water... give life.

S-4004 Intermediate Pump Station 100% review MDEQ Comments

Attached are the MDEQ review cornments for Contract S-4(4}4. Please forward thern to anyborly that | may have left off the distribution list. See you tornorrow. Daryl J. Gotham, PE. Michigan Depariment of Environmental Quality Office of Drinking Water & Municipal Assistance Saginaw-Bay Disirict Office 401 Keichum Sireei, Sulle B Bay Clty, ME 48708 989-450-8148 (Phone) 989-801-9213 Fax} xxxEND_PAGE:deq11_b411_1884_1884_1

Fwd: FW: Updated KWA Planning Calendar

John, Thought I should give you a update of the olan submittals for the Pipeline Contracts (S.4002, $.4003, 5.4005 and 5.4006). The 60% subrnittals will be as shown on the Planning Calendar with one caveat. They will be submitting only the glans on thase dates, All the specifications and PDR’s are projected to submitted on or before February 4a i still will have the plans delivered to Jon and Mike the day after they are received per the Planning Calendar and once we have received the PDR’s & Specifications, | will see that they are delivered to thern as they are received. Ary questions, please let me know. Larry A, Osborn, PE, Professional Engineer 555 S. Saginaw Street, Suite 201, Flint, Michigan 48802 £10.236,2556 direct | S1O.S16.6793 cell | 810.295.4975 fax xxxEND_PAGE:deq11_b403_1848_1850_1

MDEQ Meetings

Matt, Do you want to or would you like me to contact Jon Bloemker to let him know there will be a delay for most of the 60% Plans based on the realignment...or should we go through O’Malia? As I have it now, the schedule is as follows: ¢ December 13" — §.4007 60% plans submitted to GCDC-WWS e December 16 — §.4007 60% plans delivered to Jon Bloemker (flash drive to Mike Prysby) e December 20" — S.4001 & $.4004 90% plans submitted to GCDC-WWS ¢ December 23"? — §.4001 and $.4004 90% plans delivered to Jon Bloemker (flash drive to Mike Prysby) e January 6, 2014 - MDEQ meeting to review Pump Stations and S.4007 60% plans (10:00 am) Larry xxxEND_PAGE:deq11_b396_1836_1837_2

DEQ Meeting with Flint City

>> >> As per Mike they are going to operate the plant, with softening, starting in April 2014 when the DWSD contract expires. So, they have to move quickly to improve the plant to manage/produce water 24/7. It sounds like the design will proceed quickly to allow 24/7 operation and much is to be done quickly to meet the deadline. | am sure somethings will slip beyond April but they seem to be in a move quick mode! >> | told Mike that they would get the 60% PS drawings by say Friday the 8th as they are closed Monday. Larry, | assume that is correct. >> It appears that moving the meeting to the 21st is going to be OK for review of the PS drawings. They did not seem to have any heartburn with the standards as presented but it will be a good idea to just open that issue up, on the 21st, to be sure it is vetted. >> All seems to progress. >> Any questions let me know. >> John O'. xxxEND_PAGE:deq04_b577_6019_6376_276 Rennaker, Joanne (DEQ)

KWA Meeting Schedule

I believe we had a very productive meeting on the 10th. Covered many issues and developed scheduling that will be efficient/productive for all concerned and work within the compressed design schedule established to more the project quickly. The next meetings, including DEQ staff, are as follows: -Workshop-November Sth at GCDC at 8:00AM. The first hour, for the DEQ staff, will be devoted to a pipeline surge analysis presentation, -Pump Station Review-November 19th at 8:30AM at GCDC office. The 60% PS drawings will be submitted to GCDC 11/6 and then GCDC_ [WT] to send to both DEQ offices, -Pipeline Review-January 6, 2014 at GCDC office at 10:00AM, the 60% pipeline drawings to be delivered to GCDC on 12/13 and then GCDC [WT] to sent to both DEQ offices. I was agreed that Larry Osborn will hand carry a flash drive to both the Lansing and Saginaw DEQ offices, of the 60% plans, to expedite the review process and they to put on a LAN system as appropriate. It was agreed half size drawings are appropriate at this review stage. It was further agreed that Larry Osborn will email the pipeline PDR and Matt has sent the pipeline map. Any questions let me know. John O' xxxEND_PAGE:deq17_b125_1038_1038_1